Skip to product information
1 of 2

HARBAX 63mm Refrigerant Pressure Gauge, Centre Back Mount | Low 250 & High 500 psi

HARBAX 63mm Refrigerant Pressure Gauge, Centre Back Mount | Low 250 & High 500 psi

Regular price Dhs.35.00 AED
Regular price Sale price Dhs.35.00 AED
Sale Sold out
Shipping calculated at checkout.
Pressure Range
Quantity

The HARBAX 63 mm centre back mount refrigerant pressure gauge is a liquid-filled stainless steel panel gauge with a 1/4" SAE flare connection in the middle of the back, offered as a Low 250 psi gauge for the low side and a High 500 psi gauge for the high side. Both dials carry a vacuum scale down to -30 inHg and temperature scales for R404A, R22 and R134a, so you can read pressure and the matching saturation temperature at a glance. A 3-hole front flange around the bezel lets you set the gauge flush into a cut-out in a control panel or unit front, with the connection running straight back behind the panel.

Why Choose the HARBAX Refrigerant Pressure Gauge?

  • Two ranges: Pick the Low 250 psi gauge for the low-pressure (suction) side or the High 500 psi gauge for the high-pressure (discharge) side.
  • Refrigerant scales: Temperature scales for R404A, R22 and R134a are printed around the pressure scale.
  • Compound dial: Each gauge reads vacuum down to -30 inHg as well as positive pressure.
  • Liquid filled: The fill damps pointer vibration on running compressors.
  • Stainless steel case: A 304 stainless steel case suits plant rooms and outdoor units.
  • Class 1.6 accuracy: Marked kl 1.6 on the dial.
  • Back connection and front flange: A brass 1/4" SAE male flare on the centre back and a 3-hole front flange for flush panel mounting.

HARBAX Refrigerant Pressure Gauge Specifications

Specification Low 250 psi High 500 psi
Brand HARBAX HARBAX
Gauge type Refrigerant pressure gauge, compound scale Refrigerant pressure gauge, compound scale
Pressure range Low side, 250 psi High side, 500 psi
Bar scale on dial 0 to 15 bar 0 to 35 bar
Vacuum scale Down to -30 inHg Down to -30 inHg
Other units on dial kPa (x100) kPa (x100)
Refrigerant temperature scales R404A, R22, R134a (°C) R404A, R22, R134a (°C), marked VAPOUR
Typical use Low-pressure (suction) side High-pressure (discharge / liquid) side
Dial size 63 mm 63 mm
Accuracy class 1.6 (kl 1.6 on dial) 1.6 (kl 1.6 on dial)
Case 304 stainless steel, liquid filled 304 stainless steel, liquid filled
Connection 1/4" SAE male flare, brass, centre back mount 1/4" SAE male flare, brass, centre back mount
Mounting Centre back mount with 3-hole front (panel) flange Centre back mount with 3-hole front (panel) flange

The bar, vacuum and refrigerant scales come from the printing on each dial. Dial size, case material and accuracy come from our product records; the front flange and centre back connection are shown in the photos.

Low 250 psi or High 500 psi: How to Choose

Low 250 psi gauge (low side)

Use it on the suction or low-pressure side of the system, where pressures are lower and vacuum readings are useful during evacuation. Its bar scale reads 0 to 15 bar.

High 500 psi gauge (high side)

Use it on the discharge, condenser or liquid line, where pressures are higher. Its bar scale reads 0 to 35 bar and its temperature scales are marked VAPOUR.

Check the refrigerant

The temperature scales are for R404A, R22 and R134a. For other refrigerants, read the pressure scale and use a pressure-temperature chart for that gas.

Installation Tips

  • Fit the gauge to a 1/4" SAE female flare port or adapter and tighten with a spanner on the brass hex, not by twisting the case.
  • Cut a round hole in the panel for the case, pass the gauge through from the front and fix the 3-hole front flange with screws so the dial sits flush and upright.
  • Leave room behind the panel for the back connection and the line or capillary that feeds it.
  • Choose a range so normal working pressure sits well within the scale, and keep pressure below the full-scale value.
  • Isolate and depressurise the line before fitting or removing a gauge.

Where to Use It: Applications

  • Refrigeration control panels and unit fronts
  • Condensing units and racks with gauge panels
  • Cold rooms, freezers and display cabinets
  • AC and refrigeration service and test benches
  • Monitoring suction and discharge pressure

Why Buy HARBAX Gauges from Angstrom in Dubai?

  • Dubai-based supplier of pressure gauges and refrigeration spares, with delivery across the UAE.
  • Low 250 psi and High 500 psi gauges on one page, with the dial scales clearly listed.
  • Part of our pressure gauge and AC and refrigeration ranges.

HARBAX Refrigerant Pressure Gauge FAQ

What is the difference between the Low 250 psi and High 500 psi gauge?

The Low 250 psi gauge (0 to 15 bar scale) is for the low-pressure suction side. The High 500 psi gauge (0 to 35 bar scale) is for the high-pressure discharge and liquid line side.

Which refrigerants are on the dial?

Both dials have temperature scales for R404A, R22 and R134a in °C.

Does it read vacuum?

Yes. Both gauges have a vacuum scale down to -30 inHg.

Is the gauge liquid filled?

Yes. It has a liquid-filled 304 stainless steel case, which steadies the pointer under vibration.

What connection does it have?

A brass 1/4" SAE male flare in the centre of the back of the case.

What is the difference between centre back mount and bottom mount?

On a centre back mount gauge the connection comes straight out of the back, which suits flush panel fitting through a front flange. On a bottom (lower) mount gauge the connection is at the bottom of the case, which suits fitting directly onto a line or port. A HARBAX 60 mm bottom mount version is also in our range.

Can it be panel mounted?

Yes. The 3-hole front flange fixes it flush into a panel cut-out.

How accurate is it?

The dial is marked accuracy class 1.6.

Can I use it as an oil pressure gauge?

The dials are printed with refrigerant temperature scales, so it is intended for refrigerant pressure. The pressure scale itself can still be read on any compatible system within its range.

View full details