{"product_id":"harbax-drier-core-d48","title":"HARBAX CleanFlow 48-DC Drier Core | D48 Filter Drier Core for Liquid Line Shells","description":"\u003cp\u003e\u003cstrong\u003eThe HARBAX CleanFlow 48-DC (part number D48) is a universal replacement drier core with a 48 cubic inch desiccant volume, made for shell-type filter driers on HVAC and refrigeration systems.\u003c\/strong\u003e Its blend of molecular sieve and activated alumina gives high moisture and acid removal on liquid line and suction line installations, while keeping pressure drop low. It is a core only (some buyers search for it as a dryer core), so it goes inside a standard shell-type filter drier housing.\u003c\/p\u003e\n\u003ch2\u003eWhy Choose the HARBAX CleanFlow 48-DC Drier Core?\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh moisture and acid removal:\u003c\/strong\u003e The core adsorbs the moisture and acid that would otherwise damage the system and shorten component life.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e48 cubic inch desiccant volume:\u003c\/strong\u003e A large adsorption capacity for moisture and acid contaminants.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMolecular sieve and activated alumina blend:\u003c\/strong\u003e A high-grade mix for chemical stability and filtration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide system coverage:\u003c\/strong\u003e For commercial, industrial and residential systems, on the liquid line or the suction line.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWorks with common refrigerants and oils:\u003c\/strong\u003e CFC, HCFC and HFC refrigerants, with mineral oil, alkylbenzene and POE lubricants.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSealed tin packing:\u003c\/strong\u003e The core is packed in a tin with a pull-ring lid, and it keeps its adsorption capacity while the tin stays sealed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCleanFlow design:\u003c\/strong\u003e Keeps refrigerant moving smoothly with low pressure drop.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eHARBAX CleanFlow 48-DC Drier Core Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHARBAX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eCleanFlow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCleanFlow 48-DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart number\u003c\/td\u003e\n\u003ctd\u003eD48\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type\u003c\/td\u003e\n\u003ctd\u003eUniversal replacement filter drier core\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDesiccant volume\u003c\/td\u003e\n\u003ctd\u003e48 cubic inch (48 cu.in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDesiccant blend\u003c\/td\u003e\n\u003ctd\u003eHigh-grade molecular sieve and activated alumina\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eHigh moisture and acid removal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003eLiquid line and suction line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystems\u003c\/td\u003e\n\u003ctd\u003eCommercial, industrial and residential\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFits\u003c\/td\u003e\n\u003ctd\u003eStandard shell-type filter drier housings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerants\u003c\/td\u003e\n\u003ctd\u003eCFC, HCFC and HFC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLubricants\u003c\/td\u003e\n\u003ctd\u003eMineral oil, alkylbenzene and POE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow\u003c\/td\u003e\n\u003ctd\u003eLow pressure drop, smooth refrigerant flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackaging\u003c\/td\u003e\n\u003ctd\u003eSealed tin with pull-ring lid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupplied as\u003c\/td\u003e\n\u003ctd\u003eCore only, housing (shell) sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eRefrigerants and Lubricants\u003c\/h2\u003e\n\u003cp\u003eThe 48-DC is made for use with CFC, HCFC and HFC refrigerants. It can be used in systems that run mineral oil, alkylbenzene or POE lubricants. Check your system's refrigerant and oil before you order.\u003c\/p\u003e\n\u003ch2\u003eHow a Replaceable Drier Core Works\u003c\/h2\u003e\n\u003cp\u003eA take-apart filter drier has a shell with a removable cover and a core inside. Refrigerant flows through the core, which holds back moisture and acid. When the core is used up, you open the shell, fit a new core and close it again, instead of cutting out the whole drier.\u003c\/p\u003e\n\u003ch2\u003eSealed Tin and Pull-Ring Lid\u003c\/h2\u003e\n\u003cp\u003eThe core arrives in a sealed tin. While the tin stays sealed, the core keeps its adsorption capacity. Keep it sealed until you are ready to fit it. To open the tin, lift the pull ring, bend it back and pull the lid up.\u003c\/p\u003e\n\u003ch2\u003eWhen to Replace the Drier Core\u003c\/h2\u003e\n\u003cp\u003eReplace the core during major servicing, after contamination, and after a compressor failure. A core that has already taken up moisture and acid cannot protect the system once it is used up.\u003c\/p\u003e\n\u003ch2\u003eCheck Before You Choose\u003c\/h2\u003e\n\u003ch3\u003eThis is a core, not a complete drier\u003c\/h3\u003e\n\u003cp\u003eThe 48-DC only works inside a compatible shell-type filter drier housing. Sealed filter driers, which are replaced as a complete unit, do not take a replaceable core.\u003c\/p\u003e\n\u003ch3\u003eMatch your shell\u003c\/h3\u003e\n\u003cp\u003eCheck that your housing takes a 48 cubic inch core before you order. If you are unsure, check the shell's nameplate or the manufacturer's data.\u003c\/p\u003e\n\u003ch2\u003eWhere to Use It: Applications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCommercial, industrial and residential refrigeration and HVAC systems\u003c\/li\u003e\n\u003cli\u003eShell-type filter driers on the liquid line or suction line\u003c\/li\u003e\n\u003cli\u003eService work after contamination or a compressor change\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWhy Buy the HARBAX Drier Core from Angstrom in Dubai?\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDubai-based supplier of HVAC and refrigeration components, with delivery across the UAE.\u003c\/li\u003e\n\u003cli\u003eClear model and part numbers (CleanFlow 48-DC, D48), so you can match the core to your shell.\u003c\/li\u003e\n\u003cli\u003eSold as a core only, so you pay for the part you are replacing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eHARBAX CleanFlow 48-DC Drier Core FAQ\u003c\/h2\u003e\n\u003ch3\u003eWhat is a drier core?\u003c\/h3\u003e\n\u003cp\u003eIt is the replaceable insert inside a take-apart filter drier, also called a dryer core. It removes moisture and acid from the refrigerant.\u003c\/p\u003e\n\u003ch3\u003eWhat does the HARBAX CleanFlow 48-DC do?\u003c\/h3\u003e\n\u003cp\u003eIt removes moisture and acids from the refrigerant to protect compressors and system components.\u003c\/p\u003e\n\u003ch3\u003eWhat is the desiccant volume and what is it made of?\u003c\/h3\u003e\n\u003cp\u003eThe desiccant volume is 48 cubic inches. The core is made of a high-grade blend of molecular sieve and activated alumina.\u003c\/p\u003e\n\u003ch3\u003eWhich refrigerants and oils can I use it with?\u003c\/h3\u003e\n\u003cp\u003eIt is made for CFC, HCFC and HFC refrigerants, and for systems with mineral oil, alkylbenzene or POE lubricants.\u003c\/p\u003e\n\u003ch3\u003eCan it go on the suction line as well as the liquid line?\u003c\/h3\u003e\n\u003cp\u003eYes. The label lists liquid line and suction line installations in commercial, industrial and residential systems.\u003c\/p\u003e\n\u003ch3\u003eIs it a replacement core or a complete filter drier?\u003c\/h3\u003e\n\u003cp\u003eIt is a replacement core for use inside a compatible shell-type filter drier. The shell is a separate item.\u003c\/p\u003e\n\u003ch3\u003eCan I use it in a sealed flare filter drier?\u003c\/h3\u003e\n\u003cp\u003eNo. Sealed filter driers do not have a removable core. Replace those as a complete unit.\u003c\/p\u003e\n\u003ch3\u003eHow long does the core keep its capacity in the tin?\u003c\/h3\u003e\n\u003cp\u003eWhile the tin stays sealed, the core keeps its adsorption capacity. Open the tin only when you are ready to fit the core.\u003c\/p\u003e\n\u003ch3\u003eDoes it affect refrigerant flow?\u003c\/h3\u003e\n\u003cp\u003eNo. The CleanFlow design is made for low pressure drop and smooth refrigerant circulation.\u003c\/p\u003e\n\u003ch3\u003eWhen should I replace the drier core?\u003c\/h3\u003e\n\u003cp\u003eDuring major servicing, after contamination, and after a compressor failure.\u003c\/p\u003e","brand":"HARBAX","offers":[{"title":"Default Title","offer_id":68484588798063,"sku":"DC-HARB-D-48","price":25.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/8194\/9807\/files\/harbax-cleanflow-48-dc-filter-drier-core-front.jpg?v=1795052965","url":"https:\/\/www.angstromtrading.com\/products\/harbax-drier-core-d48","provider":"Angstrom Building Materials Trading LLC","version":"1.0","type":"link"}