{"product_id":"copper-elbow","title":"Krystal Copper Elbow 90° | AC \u0026 Refrigeration Copper Fitting | 3\/8\" to 1-1\/8\"","description":"\u003cp\u003e\u003cstrong\u003eNeed a copper elbow in the UAE?\u003c\/strong\u003e This Krystal 90° copper elbow is one of our AC copper fittings and refrigeration copper fittings, used to turn a copper pipe run through a right angle. It is made of high-grade copper, joins to the pipe by brazing, and comes in 15 sizes from 3\/8\" to 4-1\/8\", so one range covers small split-unit lines and large commercial headers.\u003c\/p\u003e\n\u003ch2\u003eWhy Choose the Krystal Copper Elbow 90°?\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRight-angle turn in one fitting:\u003c\/strong\u003e The 90° bend lets you change direction cleanly around walls, equipment and structure, without bending the pipe by hand.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCopper to match copper pipe:\u003c\/strong\u003e The fitting is the same metal as the tube, which suits brazed refrigerant lines.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrazed connection:\u003c\/strong\u003e Made for brazing, the standard way to join copper refrigerant pipework.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOne range, many line sizes:\u003c\/strong\u003e Fifteen sizes with model numbers, so you can match the fitting to the pipe you are installing and reorder the exact part later.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eProduct: Copper elbow, 90 degree\u003c\/li\u003e\n\u003cli\u003eBrand: Krystal\u003c\/li\u003e\n\u003cli\u003eMaterial: High-grade copper\u003c\/li\u003e\n\u003cli\u003eAngle: 90°\u003c\/li\u003e\n\u003cli\u003eConnection type: Brazed\u003c\/li\u003e\n\u003cli\u003eSizes: 3\/8\" to 4-1\/8\" (15 sizes, listed in the table below)\u003c\/li\u003e\n\u003cli\u003eModel numbers: KCF0303 to KCF0319, by size\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCopper Elbow Sizes and Model Numbers\u003c\/h2\u003e\n\u003cp\u003eEach elbow is sized by the copper pipe it connects to. The pipe outer diameter in millimetres is the standard conversion of the inch size.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSize (inch)\u003c\/th\u003e\n\u003cth\u003eCopper pipe OD (mm)\u003c\/th\u003e\n\u003cth\u003eModel no.\u003c\/th\u003e\n\u003cth\u003eAngle\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e3\/8\"\u003c\/td\u003e\n\u003ctd\u003e9.52\u003c\/td\u003e\n\u003ctd\u003eKCF0303\u003c\/td\u003e\n\u003ctd\u003e90°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1\/2\"\u003c\/td\u003e\n\u003ctd\u003e12.7\u003c\/td\u003e\n\u003ctd\u003eKCF0304\u003c\/td\u003e\n\u003ctd\u003e90°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5\/8\"\u003c\/td\u003e\n\u003ctd\u003e15.88\u003c\/td\u003e\n\u003ctd\u003eKCF0305\u003c\/td\u003e\n\u003ctd\u003e90°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3\/4\"\u003c\/td\u003e\n\u003ctd\u003e19.05\u003c\/td\u003e\n\u003ctd\u003eKCF0306\u003c\/td\u003e\n\u003ctd\u003e90°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e7\/8\"\u003c\/td\u003e\n\u003ctd\u003e22.22\u003c\/td\u003e\n\u003ctd\u003eKCF0307\u003c\/td\u003e\n\u003ctd\u003e90°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003ctd\u003e25.4\u003c\/td\u003e\n\u003ctd\u003eKCF0308\u003c\/td\u003e\n\u003ctd\u003e90°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1-1\/8\"\u003c\/td\u003e\n\u003ctd\u003e28.58\u003c\/td\u003e\n\u003ctd\u003eKCF0309\u003c\/td\u003e\n\u003ctd\u003e90°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1-1\/4\"\u003c\/td\u003e\n\u003ctd\u003e31.75\u003c\/td\u003e\n\u003ctd\u003eKCF0310\u003c\/td\u003e\n\u003ctd\u003e90°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1-3\/8\"\u003c\/td\u003e\n\u003ctd\u003e34.92\u003c\/td\u003e\n\u003ctd\u003eKCF0311\u003c\/td\u003e\n\u003ctd\u003e90°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1-1\/2\"\u003c\/td\u003e\n\u003ctd\u003e38.1\u003c\/td\u003e\n\u003ctd\u003eKCF0312\u003c\/td\u003e\n\u003ctd\u003e90°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1-5\/8\"\u003c\/td\u003e\n\u003ctd\u003e41.28\u003c\/td\u003e\n\u003ctd\u003eKCF0313\u003c\/td\u003e\n\u003ctd\u003e90°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1-3\/4\"\u003c\/td\u003e\n\u003ctd\u003e44.45\u003c\/td\u003e\n\u003ctd\u003eKCF0314\u003c\/td\u003e\n\u003ctd\u003e90°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2-1\/8\"\u003c\/td\u003e\n\u003ctd\u003e53.98\u003c\/td\u003e\n\u003ctd\u003eKCF0315\u003c\/td\u003e\n\u003ctd\u003e90°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3-1\/8\"\u003c\/td\u003e\n\u003ctd\u003e79.38\u003c\/td\u003e\n\u003ctd\u003eKCF0317\u003c\/td\u003e\n\u003ctd\u003e90°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4-1\/8\"\u003c\/td\u003e\n\u003ctd\u003e104.78\u003c\/td\u003e\n\u003ctd\u003eKCF0319\u003c\/td\u003e\n\u003ctd\u003e90°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eHow to Choose and Install a Copper Elbow\u003c\/h2\u003e\n\u003ch3\u003eMatch the size to the pipe\u003c\/h3\u003e\n\u003cp\u003eChoose the elbow with the same nominal size as the copper pipe you are joining. A 3\/4\" elbow goes on 3\/4\" pipe, and so on. The size is the pipe diameter, not the fitting's own outside diameter.\u003c\/p\u003e\n\u003ch3\u003eBraze with care\u003c\/h3\u003e\n\u003cp\u003eCut the pipe square, remove burrs, clean the pipe end and the fitting socket, and fit the pipe fully into the socket before heating. Heat the joint evenly and let the brazing alloy flow into the gap. For refrigerant lines, it is common practice to flow nitrogen through the pipe while brazing to limit oxide build-up inside the tube. Follow the equipment manufacturer's installation instructions and your site's procedures.\u003c\/p\u003e\n\u003ch3\u003ePlan the route\u003c\/h3\u003e\n\u003cp\u003eUse as few elbows as the layout allows, because every bend adds some resistance to refrigerant flow. Where the run is long, check the line sizes and any extra fittings against the system designer's requirements.\u003c\/p\u003e\n\u003ch2\u003eWhere to Use 90° Copper Elbows: Applications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eResidential split and ductless AC refrigerant lines\u003c\/li\u003e\n\u003cli\u003eCommercial HVAC and VRF\/VRV piping\u003c\/li\u003e\n\u003cli\u003eRefrigeration units, display chillers and cold rooms\u003c\/li\u003e\n\u003cli\u003eIndustrial refrigeration pipework\u003c\/li\u003e\n\u003cli\u003eRepair and replacement of existing copper refrigerant lines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWhy Buy a Copper Elbow 90 Degree in Dubai from Angstrom?\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDubai-based supplier of copper elbow 90 degree fittings and other HVAC components, with delivery across the UAE.\u003c\/li\u003e\n\u003cli\u003eKrystal copper fittings and Krystal copper coil from one supplier, so pipe and fittings match.\u003c\/li\u003e\n\u003cli\u003eClear model numbers and sizes, which makes it easy to specify the right fitting on a quotation or job list.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCopper Elbow FAQ\u003c\/h2\u003e\n\u003ch3\u003eWhat is a 90 degree copper elbow used for?\u003c\/h3\u003e\n\u003cp\u003eIt changes the direction of a copper pipe run by 90 degrees. In AC and refrigeration systems it routes refrigerant lines around obstacles and into equipment connections.\u003c\/p\u003e\n\u003ch3\u003eHow is the Krystal copper elbow connected to the pipe?\u003c\/h3\u003e\n\u003cp\u003eBy brazing. The pipe slides into the fitting and the joint is sealed with brazing alloy.\u003c\/p\u003e\n\u003ch3\u003eWhat sizes does the Krystal copper elbow 90° come in?\u003c\/h3\u003e\n\u003cp\u003eThe range covers 3\/8\", 1\/2\", 5\/8\", 3\/4\", 7\/8\", 1\", 1-1\/8\", 1-1\/4\", 1-3\/8\", 1-1\/2\", 1-5\/8\", 1-3\/4\", 2-1\/8\", 3-1\/8\" and 4-1\/8\". The table above gives the pipe diameter and model number for each.\u003c\/p\u003e\n\u003ch3\u003eDoes the elbow size refer to the pipe or to the fitting?\u003c\/h3\u003e\n\u003cp\u003eIt refers to the copper pipe the elbow is made for. For example, a 5\/8\" elbow is for 5\/8\" copper pipe.\u003c\/p\u003e\n\u003ch3\u003eCan I use these fittings with Krystal copper coil?\u003c\/h3\u003e\n\u003cp\u003eYes. Choose the elbow in the same nominal size as the coil you are installing, for example a 3\/8\" elbow with 3\/8\" coil.\u003c\/p\u003e\n\u003ch3\u003eDo you deliver copper fittings across the UAE?\u003c\/h3\u003e\n\u003cp\u003eYes. We are based in Dubai and deliver copper elbows and other fittings across the UAE.\u003c\/p\u003e","brand":"Krystal","offers":[{"title":"3\/8\"","offer_id":68483410919535,"sku":"CE-KRY-90-3\/8","price":0.8,"currency_code":"AED","in_stock":true},{"title":"5\/8\"","offer_id":68483410952303,"sku":"CE-KRY-90-5\/8","price":1.65,"currency_code":"AED","in_stock":true},{"title":"3\/4\"","offer_id":68483410985071,"sku":"CE-KRY-90-3\/4","price":2.6,"currency_code":"AED","in_stock":true},{"title":"7\/8\"","offer_id":68483411017839,"sku":"CE-KRY-90-7\/8","price":3.9,"currency_code":"AED","in_stock":true},{"title":"1-1\/8\"","offer_id":68483411050607,"sku":"CE-KRY-90-11\/8","price":6.5,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0652\/8194\/9807\/files\/krystal-copper-elbow-90-3-8-inch.jpg?v=1795049316","url":"https:\/\/www.angstromtrading.com\/products\/copper-elbow","provider":"Angstrom Building Materials Trading LLC","version":"1.0","type":"link"}